{"id":1926,"date":"2026-06-29T08:01:53","date_gmt":"2026-06-29T12:01:53","guid":{"rendered":"https:\/\/www.umes.edu\/ehscopy\/?page_id=1926"},"modified":"2026-07-28T11:26:39","modified_gmt":"2026-07-28T15:26:39","slug":"chemical-waste-management-guidance","status":"publish","type":"page","link":"https:\/\/www.umes.edu\/ehs\/chemical-waste-management-guidance\/","title":{"rendered":"Chemical Waste Management Guidance"},"content":{"rendered":"\n<p class=\"has-medium-font-size wp-block-paragraph\">Chemical waste management covers the safe handling, storage, accumulation, and disposal of hazardous and non-hazardous chemical waste ensuring compliance with applicable federal and state regulations. All personnel generating chemical waste are responsible for proper identification, segregation, labeling, and timely transfer of waste to designated accumulation areas to minimize risks to human health, laboratory personnel, the environment, and facility infrastructure. Waste must never be disposed of via drains or general trash unless explicitly approved by EHS.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">The classification and management structure outlined in the tables below is based on regulatory principles established under the Resource Conservation and Recovery Act (RCRA), which serves as the governing framework for hazardous waste identification and accumulation practices.<\/p>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-large-font-size\">Chemical Waste Handling, Labeling, and Storage Area Guidance<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Waste Category<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Handling and Labeling Requirements<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Storage Area Requirements<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Ignitable Waste (D001)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label: \u201cHazardous Waste \u2013 Ignitable (D001)\u201d + full chemical names. Keep closed at all times. No ignition sources.<\/td><td class=\"has-text-align-center\" data-align=\"center\">Flammable liquid storage cabinet (NFPA-rated), secondary containment required<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Corrosive Waste (D002)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label: \u201cHazardous Waste \u2013 Corrosive (D002)\u201d + pH if known. Segregate acids and bases.<\/td><td class=\"has-text-align-center\" data-align=\"center\">Corrosives cabinet with acid\/base segregation and corrosion-resistant lining<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Reactive Waste (D003)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label: \u201cHazardous Waste \u2013 Reactive (D003)\u201d with hazard description. Must indicate incompatibilities.<\/td><td class=\"has-text-align-center\" data-align=\"center\">Isolated storage area with no water sources; blast\/pressure-safe segregation<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Toxic Metals (D004\u2013D011)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label: \u201cHazardous Waste \u2013 Toxic\u201d + constituents listed. No dilution allowed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Secure hazardous waste cabinet with secondary containment and restricted access<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Toxic Organics and Pesticides (D012-D043)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label: \u201cHazardous Waste \u2013 Toxic\u201d + constituents listed. No dilution allowed<\/td><td class=\"has-text-align-center\" data-align=\"center\">Secure hazardous waste cabinet with secondary containment and restricted access<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Spent halogenated and non-halogenated solvents used in degreasing (F001-F005)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label with applicable F-code and chemical constituents. Segregate halogenated and non-halogenated solvent waste where practical.<\/td><td class=\"has-text-align-center\" data-align=\"center\">Flammable storage cabinet or designated hazardous waste storage area.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Source-specific hazardous wastes generated from certain industrial metal finishing and electroplating processes; rarely generated at universities. (F006-F012, F019)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Coordinate with EHS<\/td><td class=\"has-text-align-center\" data-align=\"center\">Coordinate with EHS<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Source-specific hazardous waste generated by certain industrial manufacturing processes, rarely generated at universities. (K-listed)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Coordinate with EHS<\/td><td class=\"has-text-align-center\" data-align=\"center\">Coordinate with EHS <\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">unused commercial acutely hazardous chemicals (P-Listed)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label with applicable P-code. Keep containers closed. Minimize accumulation. Contact EHS promptly for disposal.<\/td><td class=\"has-text-align-center\" data-align=\"center\">Dedicated EHS-controlled hazardous waste area with compatible secondary containment.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">unused commercial hazardous chemicals that are not acutely toxic (U-Listed)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Label with applicable U-code. List chemical constituents.<\/td><td class=\"has-text-align-center\" data-align=\"center\">Hazardous waste accumulation area with compatible storage.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Unknowns, unstable, and\/or unusual hazard profiles (Special Handling Waste Stream)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Requires EHS evaluation prior to containerization and must not be mixed with other hazardous waste streams<\/td><td class=\"has-text-align-center\" data-align=\"center\">Must be EHS approved and segregated based on hazard classification<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h1 class=\"wp-block-heading has-text-align-center has-large-font-size\">Chemical Waste Accumulation Area Guidance<\/h1>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Area Type<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\">Description<\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Requirements<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Satellite Accumulation Area<\/td><td class=\"has-text-align-center\" data-align=\"center\">Point-of-generation storage in labs or shops<\/td><td class=\"has-text-align-center\" data-align=\"center\">Remain at or near the point of generation under control of the generator. Containers must remain closed (except when adding waste), be properly labeled, and generally be limited to <strong>55 gallons of hazardous waste<\/strong> (or <strong>1 quart of acutely hazardous waste<\/strong>).<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Central Accumulation Area<\/td><td class=\"has-text-align-center\" data-align=\"center\">Primary campus hazardous waste storage managed by EHS<\/td><td class=\"has-text-align-center\" data-align=\"center\">Access controlled. Weekly inspections. Emergency equipment available. Waste containers dated upon arrival. Maintained in accordance with RCRA generator requirements.<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">90-day Area<\/td><td class=\"has-text-align-center\" data-align=\"center\">Accumulation area for Large Quantity Generators (if applicable)<\/td><td class=\"has-text-align-center\" data-align=\"center\">Hazardous waste may be accumulated for up to <strong>90 days<\/strong>. Containers must remain closed, labeled, dated, and inspected routinely<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Chemical waste management covers the safe handling, storage, accumulation, and disposal of hazardous and non-hazardous chemical waste ensuring compliance with applicable federal and state regulations. All personnel generating chemical waste are responsible for proper identification, segregation, labeling, and timely transfer of waste to designated accumulation areas to minimize risks to human health, laboratory personnel, the&#8230;<span class=\"cpschool-read-more-link-holder\"><a class=\"btn btn-basic cpschool-read-more-link\" href=\"https:\/\/www.umes.edu\/ehs\/chemical-waste-management-guidance\/\">Read more <span class=\"sr-only\">Chemical Waste Management Guidance<\/span><\/a><\/span><\/p>\n","protected":false},"author":4122,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","footnotes":""},"folder":[],"class_list":["post-1926","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/pages\/1926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/users\/4122"}],"replies":[{"embeddable":true,"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/comments?post=1926"}],"version-history":[{"count":0,"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/pages\/1926\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/media?parent=1926"}],"wp:term":[{"taxonomy":"folder","embeddable":true,"href":"https:\/\/www.umes.edu\/ehs\/wp-json\/wp\/v2\/folder?post=1926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}